| World Cup pumps P6, P7, and P8 | |||||||||||||
| Example model code: | |||||||||||||
| Type | P6W | -2 | R | 1 | * | -C | 0 | 0 | -BB | 0 | M2 | ||
| Standard version | P6W | ||||||||||||
| P7W | |||||||||||||
| P8W | |||||||||||||
| Test stand version | P6T | ||||||||||||
| P7T | |||||||||||||
| P8T | |||||||||||||
| Shaft | |||||||||||||
| Splined SAE-D (for W type pumps only) | -1 | ||||||||||||
| Keyed SAE-D (for W type pumps only) | -2 | ||||||||||||
| Splined AND-10266 (for T type pumps only) | -3 | ||||||||||||
| Rotation | |||||||||||||
| Clockwise | R | ||||||||||||
| Counter-clockwise | L | ||||||||||||
| Seals | |||||||||||||
| Nitrile (Buna N) | 1 | ||||||||||||
| EPR (not available when using "E" primary control) (pump | 4 | ||||||||||||
| will be unpainted unless otherwise specified) | |||||||||||||
| Flourocarbon (Viton) | 5 | ||||||||||||
| Military specification MIL-P-25732 | 6 | ||||||||||||
| Design letter (assigned by manufacturer) | * | ||||||||||||
| Primary controls | |||||||||||||
| Compensator | -C | ||||||||||||
| Load sensing compensator (50 PSI pressure drop) | -L | ||||||||||||
| Load sensing compensator (200 PSI pressure drop) | -M | ||||||||||||
| Rotary servo | -R | ||||||||||||
| Torque limiter | -T | ||||||||||||
| Hydraulic servo | -H | ||||||||||||
| Electro-hydraulic servo | -E | ||||||||||||
| Primary control options | |||||||||||||
| None (for C, L, M, R, & T primary controls only) | 0 | ||||||||||||
| Maximum volume screw (for C, L, M, & T primary controls only) | 1 | ||||||||||||
| Maximum volume handwheel (for C, L, M, & T primary controls only) | 2 | ||||||||||||
| Remote access volume adjustment (for C & T primary controls only) | 3 | ||||||||||||
| Maximum & minimum volume adjustment (for R, H, & E primary controls only) | 4 | ||||||||||||
| Secondary controls | |||||||||||||
| None | 0 | ||||||||||||
| Compensator override (for R, H, & E primary controls only) | P | ||||||||||||
| Torque limiter override (for R, H, & E primary controls only) | T | ||||||||||||
| Note: Whenever P or T are chosen, if you have an application where the pump will not | |||||||||||||
| be allowed to go to zero stroke, the installation of a special control piston cap must be | |||||||||||||
| used so that a relief valve can be fitted to ensure the pressure cannot reach | |||||||||||||
| system pressure. See circuit on page 14 of sales catalog. | |||||||||||||
| External drive | |||||||||||||
| None | -0 | ||||||||||||
| SAE-B (SAE 101-2) with SAE-B (SAE 22-4) coupling | -B | ||||||||||||
| SAE-B (SAE 101-2) with SAE-BB (SAE 25-4) coupling | -BB | ||||||||||||
| SAE-C (SAE 127-4) with SAE-C (SAE 32-4) coupling | -C | ||||||||||||
| SAE-D (SAE 152-4) with SAE-D (SAE 44-4) coupling | -D | ||||||||||||
| External mounting | |||||||||||||
| No external pump mounted | 0 | ||||||||||||
| External pump mounted (requires special modification "-M2")(must be separately specified) | 1 | ||||||||||||
| Special modification | |||||||||||||
© 2008 Rocky Mountain Hydrostatics. All rights reserved.
site designed and maintained by RayfieldCreative.
At Rocky Mountain Hydrostatics, our primary business objective is to supply remanufactured axial piston pumps on an
exchange basis, with in stock availability, 100% of the time.
All information and material posted on this Website are subject to copyrights owned by Jordan Investments, Inc., DBA Rocky Mountain Hydrostatics, Inc., (RMH).
Any reproduction, retransmission, republication, or other use of all or part of any document found
on this site is expressly prohibited, unless prior written permission has been granted by RMH. All other rights reserved.