Key Sheets
Gold Cup pumps P11 and P14
Example model code:
  P11P -2 R 1 * -40 2 -B 00 -0 B 0  
Type                          
Fixed displacement, closed circuit P11F                        
P14F                        
Fixed displacement with high torque thru-drive, closed circuit P11M                        
P14M                        
Variable displacement, closed circuit P11P                        
P14P                        
Variable displacement with high torque thru-drive, closed circuit P11R                        
P14R                        
Variable displacement with high torque thru-drive & shuttle package, closed circuit P11L                        
P14L                        
Variable displacement with medium torque thru-drive, closed circuit P11X                        
P14X                        
Variable displacement with medium torque thru-drive & shuttle package, closed circuit P11S                        
P14S                        
Variable displacement, open circuit P11V                        
P14V                        
Shaft                        
Keyed SAE - mechanical shaft seal -2 or -02                      
Splined SAE - mechanical shaft seal -3 or -03                      
Keyed SAE - double lip shaft seal -7 or -07                      
Splined SAE - double lip shaft seal -8 or -08                      
Keyed (long) SAE - double lip shaft seal -9 or -09                      
Keyed (long) SAE - mechanical shaft seal -10                      
Rotation                      
Clockwise R                    
Counter-clockwise L                    
Seals                    
Nitrile (Buna N) 1                  
EPR (not available for "5A" or "5C" primary controls)(pump unpainted unless otherwise specified)(for P*F/M) 4                  
EPR (not available for "5A" or "5C" primary controls)(pump unpainted unless otherwise specified)(for P*P/R/L/X/S/V/D) 4                  
Flourocarbon (Viton)(for P*F/M) 5                  
Flourocarbon (Viton)(for P*P/R/L/X/S/V/D) 5                  
Design letter (assigned by manufacturer) *                
Primary controls                
None (for fixed displacement units only) omit              
Screw adjustment (spring offset to maximum displacement) -10              
Cylinder control w/ adjustable maximum volume stops -2A              
Cylinder control - 3 position (spring centered with zero adjustment) -2H              
Cylinder control - 2 position electro-hydraulic w/ adjustable maximum volume stop (spring offset to maximum displ.) -2M              
Cylinder control - 3 position (spring centered) electro-hydraulic -2N              
Rotary servo - spring centered -40              
Rotary servo - spring centered w/ adjustable maximum volume stops -4A              
Rotary servo - spring centered w/ automatic brake control -4B              
Rotary servo - spring centered w/ adjustable maximum volume stops & automatic brake control -4C              
Electro-hydraulic stroker w/ adjustable maximum volume stops -5A              
Electro-hydraulic stroker w/ adjustable maximum volume stops & automatic brake control -5C              
High IQ with 10 gpm servovalve & volume indicator -7D              
High IQ with 10 gpm servovalve & 4A (rotary servo) control -7F              
High IQ with 4DC01 valve & volume indicator -7J              
High IQ with 4DC01 valve & 4A (rotary servo) control -7K              
Hydraulic stroker w/ adjustable maximum volume stops -8A              
Hydraulic stroker w/ adjustable maximum volume stops & automatic brake control -8C              
Electro-hydraulic stroker w/ adjustable maximum volume stops -9A              
Electro-hydraulic stroker w/ adjustable maximum volume stops & automatic brake control -9C              
Secondary controls              
None (for fixed displacement units only) omit            
Volume indicator 2            
Torque limiter & volume indicator 4            
Cam position feedback potentiometer 6            
Cam position feedback RVDT (DC) 8            
Control location            
None (for fixed displacement units only)               omit          
Primary control on port A side               -A          
Primary control on port B side               -B          
Control and displacement features          
2M* & 2N* controls          
4D01 valve, 110VAC/60Hz with Hirschmann connector 00        
4D01 valve, 12VDC with Hirschmann connector 01        
4D01 valve, 240VAC/50Hz with Hirschmann connector 02        
4D01 valve, 110VAC/60Hz, wiring box 03        
4D01 valve, 12VDC, wiring box 04        
Cetop3 (D03)(NG6) interface, no directional valve 05        
4D01 valve, 24VDC with Hirschmann connector 06        
4D01 valve, 110VAC/50Hz with Hirschmann connector 07        
5** controls          
with deadband 00        
without deadband 01        
7** controls          
without manual override shutoff 00        
with manual override shutoff (required for F & K primary options) 01        
8** controls          
75 - 350 psi (5 - 24 bar) 00        
75 - 435 psi (5 - 30 bar) 01        
100 - 380 psi (7 - 26 bar) 02        
150 - 400 psi (10 - 28 bar) 03        
75 - 250 psi (5 - 17 bar) 04        
9** controls          
24VDC 00        
12VDC 01        
All other controls 00        
Reduced displacement options for P*F & P*M          
Standard cam (19-degree) 00        
P11 with 17-degree cam {9.7 cu.in./rev. (160 cc/rev.)} 10        
P14 with 17-degree cam {12.5 cu.in./rev. (205 cc/rev.)} 10        
P11 with 15-degree cam {8.5 cu.in./rev. (140 cc/rev.)} 20        
P14 with 15-degree cam {10.9 cu.in./rev. (179 cc/rev.)} 20        
Internal pump        
1.07 cu.in./rev. (17.5 cc/rev.) (for P*V only) (omit if no external drive is required) -0      
2.14 cu.in./rev. (35 cc/rev.) (for P*P/S/X only) (omit if no external drive is required) -0      
No internal pump (standard on P*R/L/F/M)(no price adder for P*R/L/F/M units) -X      
External drive      
None omit    
Blanking plate (for P*S/X only)(contains an SAE-B mount) M    
SAE-A (SAE 82-2)(for P*S/X/R/L/M only) (no price adder for P*R/L) A    
SAE-B (SAE 101-2 for P*S/X)(SAE 101-2 & SAE 101-4 for P*R/L/M) (no price adder for P*R/L) B    
SAE-C (SAE 127-2 & SAE 127-4)(for P*R/L/M only) C    
SAE-D (SAE 152-4)(for P*R/L/M only) D    
SAE-E (SAE 165-4)(for P*R/L/M only) E    
External mounting    
No external pump mounted (omit if no external drive is required) 0  
External pump mounted (requires special modification "-M2")(must be separately specified) 1  
Special modification  
None omit
No paint -NP
Other special modification (examples: bronze caged barrel bearing for low viscosity fluids, tandem pumps, etc.)       -M2
*Consult Factory for Pricing TB Vane Pump
Reclamation system
5 psi check valve